Biopanda Reagents New Banner

Rotavirus and Adenovirus Combo Rapid Test CE Marking


Product Number: RAPG-RAV-001

Pack size

10 tests

Product Description

The Biopanda Rotavirus and Adenovirus Rapid Combo test qualitatively detects for the presence of Rotavirus and Adenovirus in human faecal samples to aid in the diagnosis of rotavirus or adenovirus infection. This test applies lateral flow immuno-chromatography and is for professional in vitro diagnostic use.

Test Attributes

  • Faecal samples may be used for testing
  • Results available in only 10 minutes
  • Easy to use
  • Results can be read visually
  • No need for an analyser
  • Cost effective method for assisting in the diagnosis of Rotavirus and Adenovirus Infections

Test Procedure

  1. Allow the cassette to come to room temperature and remove the cassette from its foil wrapping and place on a flat, clean surface.
  2. Collect the faecal specimen.
  3. Holding the sample collection device upright, carefully break off the tip.
  4. Squeeze 2 drops (80 µl) of the sample solution in the specimen well of the cassette, as in the illustration.
  5. Read the test results at 10 minutes. Results read after 10 minutes are considered invalid.

     

Adenovirus Rapid Test

Principle

The Biopanda Rotavirus and Adenovirus Combo Rapid Test is a qualitative, lateral flow immunoassay for the detection of rotavirus and adenovirus in human faecal samples.
In this test, the membrane is pre-coated with anti-rotavirus antibody on the R test line region of the test and anti-adenovirus antibody on the A test line region of the test. During testing, the specimen reacts with the particle coated with anti-rotavirus antibody and anti-adenovirus antibody. The mixture migrates upward on the membrane chromatographically by capillary action to react with anti-rotavirus antibody and anti-adenovirus antibody on the membrane and generates a blue or red line. The presence of these coloured lines in the test line region indicates a positive result, while their absence indicates a negative result. To serve as a procedural control, a coloured line will always appear in the control line region indicating that proper volume of specimen has been added and membrane wicking has occurred.

Performance Characteristics


Rotavirus

  • Relative sensitivity: >99.9%
  • Relative specificity: 97.8%

Adenovirus

  • Relative sensitivity: >99.9%
  • Relative specificity: 99.5%

Storage Conditions

Store the kit between 2-30°C and ensure the kits are not frozen or stored in direct sunlight. The test is valid until the expiration date printed on the foil wrapping.


Please click on "button" below for pricing to be sent to you.

                      Pricing button

Biopanda Reagents is a test kit provider.
Customer satisfaction is our top priority.
  Biopanda Product Catalogue
Register for updates


 
Stay Connected
Facebook Linkedin

Manufacture
and market

quality reagents


Excellent Service

full technical
support